What should I do if the floor at home is not hot? Summary of popular solutions across the network in 10 days
In the past 10 days, the issue of "whether the floor heating at home is hot" has become a hot topic in winter home life. The following are common causes and solutions compiled across the entire network to help you troubleshoot problems quickly.
1. Statistics on common causes of geothermal failure (data in the past 10 days)

| Cause classification | frequency of occurrence | Typical performance |
|---|---|---|
| clogged pipes | 42% | Some rooms are not hot/heat up slowly |
| Water supply temperature is insufficient | 28% | The whole house temperature is not up to standard |
| The air is not exhausted | 18% | Abnormal noise in the pipe/partially not hot |
| Water distributor failure | 8% | Single circuit is not hot/valve failure |
| Insulation layer problem | 4% | Loss of heat quickly |
2. Step-by-step solution
Step One: Basic Check
1. Check the temperature of the water supply pipe entering the home (normally should be ≥45℃)
2. Confirm that each valve of the water distributor is open
3. Observe the pressure gauge (normal value 1.5-2Bar)
Step 2: Exhaust operation
1. Close all branch valves
2. Exhaust in a single way (using a dedicated exhaust valve)
3. Exhaust until there are no bubbles in the water and then close it.
| Tool preparation | Operational points | Things to note |
|---|---|---|
| exhaust key | Turn counterclockwise 1/4 turn | Water container below |
| towel | Control water flow speed | Prevent burns |
Step 3: In-depth processing
1.Pipe cleaning: Professional pulse cleaning (recommended 2-3 years/time)
2.Filter cleaning: Clean the Y-type filter after closing the valve
3.System debugging: Balance the flow of each branch (recommended to be operated by professionals)
3. Recently popular auxiliary solutions
1.Intelligent temperature control system: Can be adjusted remotely via mobile phone (recommendation rate 89% by netizens)
2.Floor heating reflective film: Improve thermal efficiency (measured temperature rise 1-3℃)
3.Pipeline anti-scaling agent: Prevent scale accumulation (suitable for hard water areas)
| Auxiliary products | average price | Effective time |
|---|---|---|
| wireless thermostat | 200-500 yuan | Instant |
| Aluminum foil reflective film | 3-8 yuan/㎡ | 24 hours |
| magnetic filter | 150-300 yuan | 7-15 days |
4. Precautions
1. It is strictly prohibited to release water privately as a means of heating (it will cause the system to lose pressure)
2. If there is persistent lack of heat, contact the property management company to check the heat source.
3. In old communities, it is recommended to prioritize outdoor pipe insulation
According to maintenance data statistics in the past 10 days, 90% of geothermal problems can be solved through independent exhaust and cleaning. If trying the above methods still doesn't work, it is recommended to contact a professional floor heating company for system diagnosis. During the winter heating period, it is recommended to check the status of the water distributor once a week to keep the geothermal system running efficiently.